The big and well visible
emergency-stop-button is standard at all lt-models, placed at the
handrail for easy access. All oversize running machines are equipped
with this feature as well. The emergency-stop-button can be retro-fitted
at all other h/p/cosmos running machines.
Extract from the norm EN 957-6:
The push-button type or pull cord safety stop actuator shall be in a
reachable position in front of the user and in an area of ± 180 mm
parallel to the centreline of the running surface.
If the push-button type safety stop actuator is outside this area it
shall be duplicated on the opposite side except when a pull-cord
actuator is provided.
h/p/cosmos can supply a second and additional push button emergency stop
button and/or a pull-cord actuator (safety lanyard with magnetic stop)
and/or a safety arch with chest belt, harness and fall stop function.
At all models of the category medical the main push button
emergency-stop is simultaneously an emergency-off, that means by pushing
this button the power supply of the device gets cut off. |
Emergency stop with magnet switch
Emergency stop at user terminal |